Skip to main content Skip to navigation

A/C Re-New

Boosts compressor performance and provides new additive technology for enhanced system stability.
• For use in air conditioning and heat pump systems only
• Ideally formulated to be used with R-454B, R-32, R-410A, R-407C, R-22 and others
• Improves compressor performance
• Optimized lubrication improves compressor service life
• Improves energy of compressors in service
• Quiets noisy compressors
• New additive technology improves system stability
• Aids sticking reversing valves and TEVs caused by friction
• Ideal for new systems or to address a system in service
• Two types available – liquid and Connect Inject versions
• Single dosage treats up to 5 tons. Multiple dosages are required for larger systems

Description:

A/C Re-New has been successfully used for many years to
improve the performance of air conditioning and heat pump
systems. A/C Re-New provides several benefits including
savings in energy usage, quiets noisy systems, improves the
service life of the system by optimizing compressor lubrication,
resolves sticking TEVs or reversing valves in heat pumps that
are not modulating correctly due to friction.

A/C Re-New has been enhanced for the latest generation of
refrigerants. For example, R-454B contains an unsaturated
carbon-carbon molecule (HFO) unlike R-410A, its predecessor.
This unsaturated carbon-carbon molecule leads to reduced
levels of stability both in the atmosphere and in refrigerant
system operation. Certain unplanned chemicals that exist in
the refrigerant system can accelerate the degradation of the
refrigerant and lubricant in the system. Additive response in
lubricants used in refrigerants containing HFO refrigerants
(used in R-454B) needs to be considered.

In addition to providing its traditional benefits, A/C Re-New is
now formulated to maintain system stabilization due to various
operational stresses and chemical interactions. A/C Re-New is
a two-in-one product ideal for proactive treatment for new or
in service systems to provide enhanced system stabilization and
compressor lubrication.

Packaging Size Part Number Additional Info
4 fluid ounce can 4057-55
A/C Re-New Connect Inject 4057-56
Connect Injector Tool 4155-01

Directions:

This product must be used in accordance to the following directions by HVACR professionals only.

Unpressurized product can be used for R-22 / R-407C / R-410A.

Use of the A/C Re-New Injector Tool (4057-99) is recommended for installation.

  1. Secure hose-end to suction side fitting, with valve in closed position. Once attached, crack valve quickly to purge.
  2. Add 4 fl. oz. to cylinder and the close cylinder lid to seal.
  3. Install A/C Re-New
    a) Attach a vacuum pump to the other end, as shown, using another short hose with a shut-off valve. Draw vacuum on extra hose, then close its valve. Proceed to step 4.
    b) As an alternative method without the vacuum pump, use a clean manifold hose set and proper service techniques to push the A/C Re-New into the low side with high side pressure. Be sure to purge or “burp” all lines.
  4. a) Attach to high side and then briefly open valve on second hose to pressurize the cylinder of product. Close valve.
    b) Slightly open valve on cylinder to push product into system low side.
  5. Once installed, close this valve and disconnect from low side fitting.
  6. Close up cylinder to prevent any contamination from entering it.

Product Information:

Literature Downloads

Download the product bulletin and other relevant literature here.

Labels

Download a low resolution file of the product label here.

Product Safety

RTK Information

2611 Schuetz Rd. St. Louis, MO 63043
  • Telephone: 800.554.5499
  • Email: [email protected]
  • Hours: Mon–Fri: 8:00am - 5:00pm (Central Time)

We'd love to hear from you.

We'd love to hear from you.

Click the box to submit